FDA device news · Product code DYB
FDA 510(k) clearance
VStick™ Vascular Access Set (K253741): Argon Medical Devices, Inc. 510(k) clearance
Athens, TX
- Decision
- Substantially Equivalent
- Decision date
- Dec 15, 2025
- Received
- Nov 24, 2025
- 510(k) type
- Special
- Product code
- DYBIntroducer, Catheter
- Review panel
- Cardiovascular
- Device class
- Class II
- Regulation
- 21 CFR 870.1340
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 21 daysreceipt to decision, calendar days
- Median in DYB
- 64 daysthe latest 24 other decisions
- DYB decisions
- 19in the last 12 months
- Applicant’s 510(k)s
- 21in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- The V•Stick Vascular Access Set is a kit of coaxial introducer sets, a 21-gauge entry needle, and a 0.018-inch guidewire. The introducer is a thin tube that sits in a blood vessel to give access for other devices. This submission changes only the guidewire: the earlier nitinol guidewire tip with palladium/rhenium coating is replaced by a nitinol core with a stainless steel coil tip.
- What it’s cleared for
- The device is cleared for the introduction and placement of guidewires and/or catheters. The summary does not name the users or the setting beyond this.
- How it differs
- The main difference is the guidewire. The palladium/rhenium nitinol guidewire is removed and replaced with a nitinol core and stainless steel coil tip guidewire. The summary says all other components are unchanged and the intended use is the same as the predicate.
- Testing the summary lists
- Needle performance testing (dimensions, ultrasound visibility, puncture force, hub retention), leveraged from K130730
- Biocompatibility (ISO 10993-4, -5, -10, -11), leveraged from K130730 and K223791
- Animal testing not required; clinical testing not required
- The company states all acceptance criteria were met
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K253741 took 21 calendar days from receipt to decision. Of the latest 24 other decisions in product code DYB, 22 took longer, 2 were faster; their median was 64 days.
Latest decisions in DYB
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K262674 | Giranel Guiding Sheath SetKossel Medtech (Suzhou) Co., Ltd. · Traditional | Oct 15, 202677 days |
| K253526 | NAMIC Dilator and SheathMedline Industries, LP · Traditional | Jul 29, 2026258 days |
| K261529 | Micropuncture Kit / Micropuncture Access Kit / Micropuncture Introducer Set/ Microintroducer Kit / Microintroducer Kit (SIS05C); Micropuncture Kit / Micropuncture Access Kit / Micropuncture Introducer Set / Microintroducer Kit / Microintroducer Kit (IS01); Introducer Kit / Microintroducer Kit / Introducer Set /Microintroducer Set / Micro Introducer Sheath Set / Introducer Sheath Set (NIS04)Hartman Medical Group, LLC · Traditional | Jul 6, 202659 days |
| K261242 | SimplGuidePendracare · Traditional | Jun 25, 202671 days |
| K261950 | Health Line Tearaway IntroducerHealth Line International Corporation · Traditional | Jun 22, 202612 days |
| K261492 | FieldFlex Steerable SheathCenterPoint Systems, LLC · Special | Jun 5, 202630 days |
| K260606 | Echo Large Bore Introducer SheathEcho Medical, LLC · Traditional | Apr 29, 202664 days |
| K254248 | Introducer Sheath SetCardiocycle Medical(Suzhou) Co., Ltd. · Traditional | Apr 23, 2026115 days |
| K254279 | Edwards eSheath+ introducer setEdwards Lifesciences · Traditional | Apr 17, 2026108 days |
| K260091 | Aventus Introducer SheathInquis Medical · Traditional | Apr 13, 202691 days |
Other 510(k)s from Argon Medical Devices, Inc.
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K263678 | Option™ELITE Vena Cava Filter System; Option™ELITE Vena Cava Filter 100cm SystemArgon Medical Devices, Inc. · Special | Nov 5, 202629 days |
| K252795 | ZeniCore™ Automatic Biopsy Instrument (863212100 / ZeniCore Automatic Biopsy Device 12ga x 10cm with Coaxial Introducer Kit, 863212130 / ZeniCore Automatic Biopsy Device 12ga x 13cm with Coaxial Introducer Kit, 863214100 / ZeniCore Automatic Biopsy Device 14ga x 10cm with Coaxial Introducer Kit); ZeniCore™ Automatic Biopsy Instrument (863214130 / ZeniCore Automatic Biopsy Device 14ga x 13cm with CoaxialArgon Medical Devices, Inc. · Traditional | Feb 23, 2026174 days |
| K260028 | CLEANER™ Vac Thrombectomy System, CLEANER™ Vac Aspiration Catheter with Handpiece, CLEANER™ Vac Aspiration CanisterArgon Medical Devices, Inc. · Special | Feb 5, 202631 days |
| K251318 | VariFuse Adjustable Infusion CatheterArgon Medical Devices, Inc. · Traditional | Jan 20, 2026266 days |
| K242612 | Option ELITE Vena Cava Filter System (352506070E 352506100E)Argon Medical Devices, Inc. · Special | Sep 10, 20247 days |
| K241145 | TLAB® Transvenous Liver Biopsy System (TF-18C)Argon Medical Devices, Inc. · Traditional | Aug 1, 202498 days |
| K233909 | Cleaner™ Plus 18F Thrombectomy System - Cleaner™ Plus 18F Aspiration Catheter, Cleaner™ Plus 18F Handpiece with Maceration Wire, Cleaner™ Plus 18F Aspiration CanisterArgon Medical Devices, Inc. · Traditional | Mar 28, 2024107 days |
| K232679 | Cleaner™ Pro Thrombectomy System; Cleaner™ Pro Aspiration Catheter with Handpiece; Cleaner™ Pro Aspiration CanisterArgon Medical Devices, Inc. · Traditional | Jan 19, 2024140 days |
| K233432 | 10F Sheath and Dilator SetArgon Medical Devices, Inc. · Traditional | Dec 8, 202357 days |
| K232443 | Single-Loop Snare Retrieval Kit, Triple-Loop Snare Retrieval KitArgon Medical Devices, Inc. · Special | Sep 7, 202324 days |
| K223176 | Cleaner Plus™ Thrombectomy System, Cleaner Plus™ Aspiration Catheter, Cleaner Plus™ Handpiece with 65cm Maceration Wire, Cleaner Plus™ Handpiece with 135cm Maceration Wire, Cleaner Plus™ Aspiration CanisterArgon Medical Devices, Inc. · Special | Apr 10, 2023181 days |
| K211798 | Cleaner Plus Thrombectomy SystemArgon Medical Devices, Inc. · Traditional | Feb 24, 2022259 days |
Watch DYB in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get DYB every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in DYB. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K253741Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:DYBRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:DYBRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:DYB AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Argon Medical Devices, Inc."Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil