FDA device news · Product code SDO

FDA 510(k) clearance

xStep (xStep) (K253638): Spinex, Inc. 510(k) clearance

Fremont, CA

Follow SDO: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Decision
Substantially Equivalent
Decision date
Apr 20, 2026
Received
Nov 19, 2025
510(k) type
Traditional
Product code
SDOTranscutaneous Electrical Spine Stimulator To Improve Skeletal Muscle Strength And Sensation
Review panel
Physical Medicine
Device class
Class II
Regulation
21 CFR 890.5851
Third-party review
No
Summary or statement
Summary
Review time
152 daysreceipt to decision, calendar days
Median in SDO
197 daysthe latest 3 other decisions
SDO decisions
2in the last 12 months
Applicant’s 510(k)s
1in openFDA, this one included

In plain English Written by AI

What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.

What it is
The xStep is a transcutaneous electrical spinal cord stimulator, meaning it delivers electrical pulses through the skin via external hydrogel electrodes placed along or near the spine.
What it’s cleared for
The xStep is cleared to deliver programmed transcutaneous spinal cord stimulation together with functional task practice in a clinic, to improve hand sensation and strength. It is for prescription use in patients aged 18 to 75 with a chronic, non-progressive incomplete cervical spinal cord injury (C2-C8), graded B, C or D on the ASIA Impairment Scale, and is used in a medical center.
Compared with (the predicate)
  • DEN240014, ARC EX
How it differs
The summary says the xStep has two channels instead of four, a narrower biphasic amplitude range (0-200 mA versus 0-250 mA), a fixed 30 Hz frequency instead of 0.2-100 Hz, a fixed 1 ms pulse width instead of 0.1-5 ms, and manual ramp-up instead of a 2-60 second ramp-up. It also has a fixed 60 minute program duration instead of 1-180 minutes.
Testing the summary lists
  • Electrical safety and EMC (IEC 60601-1, IEC 60601-1-2, IEC 60601-2-10, ANSI C63.4)
  • Software verification and validation (IEC 62304)
  • Battery safety (IEC 62133-2)
  • Mechanical and packaging testing (push, impact, and drop testing per IEC 60601-1)

Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.

How the review time compares

Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.

K253638 took 152 calendar days from receipt to decision. Of the latest 3 other decisions in product code SDO, 3 took longer; their median was 197 days.

Latest decisions in SDO

NumberDevice and applicantDecision and review time
K253638 xStep (xStep)Spinex, Inc. · Traditional Apr 20, 2026152 days
K252893 ExaStim® Stimulation System (EXA-001, EXA-011); ReCure® Electrode Pad (PAD-003, PAD-013)Aneuvo · Traditional Mar 27, 2026197 days
K251821 ARC-EX SystemOnward Medical, Inc. · Traditional Nov 14, 2025154 days
DEN240014 ARC-EX SystemOnward Medical, Inc. · Direct Dec 19, 2024266 days

Other 510(k)s from Spinex, Inc.

The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.

This is the only 510(k) in openFDA under this applicant name.

Watch SDO in DeviceVigil

DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.

Add to Chrome — free Add to Edge

Get SDO every Monday

One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in SDO. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.