FDA device news · Product code GEX
FDA 510(k) clearance
Holmium Laser Therapeutic Apparatus (HZ-40) (K253633): Guangzhou Potent Medical Equipment Joint-Stock Co., Ltd. 510(k) clearance
Guangzhou, CN
- Decision
- Substantially Equivalent
- Decision date
- Jan 24, 2026
- Received
- Nov 19, 2025
- 510(k) type
- Traditional
- Product code
- GEXPowered Laser Surgical Instrument
- Review panel
- General, Plastic Surgery
- Device class
- Class II
- Regulation
- 21 CFR 878.4810
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 66 daysreceipt to decision, calendar days
- Median in GEX
- 90 daysthe latest 25 other decisions
- GEX decisions
- 66in the last 12 months
- Applicant’s 510(k)s
- 7in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- The HZ-40 is a pulsed solid-state Holmium:YAG laser system that delivers light at a wavelength of 2100 nm through optical fibers. The laser is used for cutting, removing, and sealing soft tissue and for breaking up stones.
- What it’s cleared for
- The device is cleared for surgical procedures using open, laparoscopic, and endoscopic methods to incise, excise, resect, ablate, vaporize, coagulate, and stop bleeding in soft tissue, and to fragment stones. The summary lists use in urology, gastroenterology, ENT, gynecology, and general surgery.
- Compared with (the predicate)
- How it differs
- The summary says the HZ-40 has a different power supply from the predicate devices, a higher maximum average power than the primary predicate (40W compared with 30W), and a different aiming beam (a green diode laser in the predicates, with the HZ-40 aiming beam at 520 nm plus or minus 10 nm, Class 3R).
- Testing the summary lists
- Electrical safety (IEC 60601-1:2005 + A1:2012 + A2:2020)
- Electromagnetic compatibility (IEC 60601-1-2:2014 + A1:2020)
- Laser equipment safety (IEC 60601-2-22:2019)
- Laser product classification and safety (IEC 60825-1:2014)
- Software life cycle (IEC 62304:2006 + A1:2015)
- Software documentation per FDA guidance for software in medical devices (May 2005)
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K253633 took 66 calendar days from receipt to decision. Of the latest 25 other decisions in product code GEX, 20 took longer, 5 were faster; their median was 90 days.
Latest decisions in GEX
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K262886 | Single Use Optical FiberQuanta System Spa · Special | Nov 5, 202680 days |
| K263063 | B`orze Inc Laser Family (Sorren/Adonis)Borze, Inc. · Traditional | Oct 30, 202659 days |
| K262349 | Diode laser device (DT25-BI, DT212-BI, DT213-BI, DT214-BI, DT215-BI)Risu Medical Technology Co., Ltd. · Traditional | Oct 27, 2026109 days |
| K262627 | Fractional CO2 Laser Therapy System (Z121)Sanhe PERFECTLASER Technology Co., Ltd. · Traditional | Oct 26, 202689 days |
| K262701 | PicoPeak Picosecond Nd:Yag Laser System (Bella-9)Beijing Sea Heart International Science and Technologyco.Ltd · Traditional | Oct 22, 202683 days |
| K262628 | Picosecond Laser treatment system (Z180)Sanhe PERFECTLASER Technology Co., Ltd. · Traditional | Oct 20, 202683 days |
| K261572 | Nd:YAG & Alexandrite Long Pulse Laser Therapy Instrument (LPDuo)Keyue (Hangzhou) Medical Information Technology Co., Ltd. · Traditional | Oct 13, 2026154 days |
| K262346 | CureLight Medical Diode Laser Systems (S3-BF45, S2-B30, S3-BF30, S2-F15, S2-H7.5)Wuhan Phomed Technology Co., Ltd. · Traditional | Oct 8, 202690 days |
| K261692 | Diode Laser Hair Removal Machine (QDTM-03)Beijing Nubway S&T Co., Ltd. · Traditional | Oct 7, 2026138 days |
| K254199 | PicoreMax (PicoreMax)BLUECORE COMPANY Co., Ltd. · Traditional | Sep 24, 2026269 days |
Other 510(k)s from Guangzhou Potent Medical Equipment Joint-Stock Co., Ltd.
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K253951 | Holmium Laser Therapeutic Apparatus (HZ-A, HZ-B, HZ-E)Guangzhou Potent Medical Equipment Joint-Stock Co., Ltd. · Traditional | Mar 6, 202686 days |
| K252771 | Holmium Laser System (Potent HP90, Potent HP100, Potent HP9120, Potent HP140, Potent HP150)Guangzhou Potent Medical Equipment Joint-Stock Co., Ltd. · Traditional | Nov 24, 202583 days |
| K252787 | Thulium Fiber Laser System (TFL-A, TFL-B)Guangzhou Potent Medical Equipment Joint-Stock Co., Ltd. · Traditional | Nov 24, 202583 days |
| K253007 | Laser Fiber (PT-OF-A-S, PT-OF-B-S, PT-OF-C-S, PT-OF-D-S, PT-OF-E-S, PT-OF-F-S)Guangzhou Potent Medical Equipment Joint-Stock Co., Ltd. · Traditional | Nov 20, 202562 days |
| K242888 | Electrohydraulic Lithotriptor (TCS-B3-II)Guangzhou Potent Medical Equipment Joint-Stock Co., Ltd. · Traditional | Mar 21, 2025179 days |
| K243032 | EHL Probe (SCDG-AS, SCDG-BS, SCDG-CS)Guangzhou Potent Medical Equipment Joint-Stock Co., Ltd. · Traditional | Mar 21, 2025175 days |
Watch GEX in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get GEX every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in GEX. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K253633Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:GEXRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:GEXRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:GEX AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Guangzhou Potent Medical Equipment Joint-Stock Co., Ltd."Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil