FDA device news · Product code FIE

FDA 510(k) clearance

Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 15G x 30mm (1530VSMM); Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 15G x 38mm (1538VSMM); Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 16G x 30mm (1630VSMM); Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 16G x 38mm (1638VSMM); Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 17G x 30mm (1730VSMM); Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 17G x 38mm (1738VSMM) (K253469): Mozarc Medical Us, LLC 510(k) clearance

Mansfield, MA

Follow FIE: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Decision
Substantially Equivalent
Decision date
Aug 6, 2026
Received
Oct 10, 2025
510(k) type
Traditional
Product code
FIENeedle, Fistula
Review panel
Gastroenterology, Urology
Device class
Class II
Regulation
21 CFR 876.5540
Third-party review
No
Summary or statement
Summary
Review time
300 daysreceipt to decision, calendar days
Median in FIE
97 daysthe latest 24 other decisions
FIE decisions
1in the last 12 months
Applicant’s 510(k)s
1in openFDA, this one included

In plain English Written by AI

What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.

What it is
The Ritus Safety Fistula Cannula with Anti-Reflux Valve is a needle-based access device. It has a stainless-steel puncture needle inside a polypropylene cannula (a thin flexible tube).
What it’s cleared for
It is cleared to gain percutaneous vascular access (entry through the skin into a blood vessel) via an arteriovenous (AV) fistula, a surgical connection between an artery and a vein, for removing and returning blood during dialysis. It is for patients 18 years or older with kidney failure.
Compared with (the predicate)
  • K142564, JMS SysLoc MINI A.V. Fistula Needle Set (V4)
  • K052267, SUPERCATH V
How it differs
The summary says the device adds a polypropylene V-plug that the predicate does not have, and uses a polycarbonate and stainless-steel safety cap instead of the predicate's polypropylene cap. The summary says flow rate differences are due to these material differences.
Testing the summary lists
  • Biocompatibility (ISO 10993-1:2018)
  • Nonclinical performance testing (ISO 10555-1:2023, ISO 10555-5:2013, ISO 9626:2016, ISO 80369-1:2018)
  • Comparative hemolysis and static flow rate testing against the predicate
  • Prospective, multicenter, single-arm clinical study at three U.S. hemodialysis centers with 38 subjects and 1,148 sessions

Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.

How the review time compares

Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.

K253469 took 300 calendar days from receipt to decision. Of the latest 24 other decisions in product code FIE, 3 took longer, 21 were faster; their median was 97 days.

Latest decisions in FIE

NumberDevice and applicantDecision and review time
K253469 Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 15G x 30mm (1530VSMM); Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 15G x 38mm (1538VSMM); Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 16G x 30mm (1630VSMM); Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 16G x 38mm (1638VSMM); Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 17G x 30mm (1730VSMM); Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 17G x 38mm (1738VSMM)Mozarc Medical Us, LLC · Traditional Aug 6, 2026300 days
K251877 JMS CAVEO A.V. Fistula Needle SetJMS North America Corporation · Traditional Aug 15, 202558 days
K213015 DORA Disposable A.V. Fistula Needle SetsBain Medical Equipment (Guangzhou) Co., Ltd. · Traditional Apr 8, 2022200 days
K171505 Dimesol Disposable AV Fistula Needle Set (Non-Safety Series) and Dimesol Disposable AV Fistula Needle Set (Safety Series)Dimesol, Inc. · Traditional May 17, 2018359 days
K163025 DORA Disposable A.V. Fistula Needle SetsBain Medical Equipment (Guangzhou) Co., Ltd. · Traditional Jul 20, 2017262 days
K151017 JMS Harmony A.V. Fistula Needle SetJMS North America Corporation · Special May 13, 201527 days
K131950 ANGEL TIP SAFETY INTRAVASCULAR NEEDLE SETSummit International Medical Technologies, Inc. · Traditional Jan 16, 2015568 days
K142564 JMS SysLoc MINI A.V. Fistula Needle Set (V4), JMS SysLoc MINI Apheresis Needle Set (V4)JMS North America Corporation · Special Dec 23, 2014103 days
K134019 MEDISYSTEMS ONESITE DUAL LUMEN NEEDLE WITH MASTERGUARD ANTI-STICK NEEDLE PROTECTOR, MEDISYSTEMS ONESITE DUAL LUMEN BUTTONxstage Medical, Inc. · Traditional Sep 11, 2014255 days
K112734 APLAN A.V. FISTULA NEEDLE SETAplan Well Enterprise Co., Ltd. · Traditional Apr 24, 2012217 days

Other 510(k)s from Mozarc Medical Us, LLC

The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.

This is the only 510(k) in openFDA under this applicant name.

Watch FIE in DeviceVigil

DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.

Add to Chrome — free Add to Edge

Get FIE every Monday

One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in FIE. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.