FDA device news · Product code BTR

FDA 510(k) clearance

Spiro-VISTA (K253437): Spiro Robotics 510(k) clearance

Hayward, CA

Follow BTR: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Decision
Substantially Equivalent
Decision date
Jun 12, 2026
Received
Oct 1, 2025
510(k) type
Traditional
Product code
BTRTube, Tracheal (W/Wo Connector)
Review panel
Anesthesiology
Device class
Class II
Regulation
21 CFR 868.5730
Third-party review
No
Summary or statement
Summary
Review time
254 daysreceipt to decision, calendar days
Median in BTR
248 daysthe latest 24 other decisions
BTR decisions
2in the last 12 months
Applicant’s 510(k)s
1in openFDA, this one included

In plain English Written by AI

What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.

What it is
The Spiro-VISTA is a servo-controlled tracheal intubation platform, meaning motors steer the device's flexible tip. It has a handheld base with a video camera, a single-use channeled laryngoscope blade with controls, and a single-use flexible intubation scope (FIS) with a second camera.
What it’s cleared for
The Spiro-VISTA is cleared as an aid in placing an endotracheal tube during non-difficult and difficult tracheal intubation. It is for use in hospitals in adults who have been clinically evaluated for ETT sizes 5.0 to 7.0 mm internal diameter.
Compared with (the predicate)
  • K110962, Ambu® aScope™ 2/Ambu® aScope™ Monitor
How it differs
The summary says the Spiro-VISTA has a wider field of view (120 degrees versus 80 degrees), a smaller outer shaft diameter (4.7 mm versus 5.4 mm), a shorter working length (330 mm versus 630 mm), and a 1.0 mm working channel versus 0.8 mm. It also shows a second video feed from the video laryngoscope and can be mounted differently on the display.
Testing the summary lists
  • Sterilization, package integrity and shelf life (ISO 11135, ISO 11607-1, ASTM D4169, ASTM F1980)
  • Biocompatibility (ISO 10993-5, ISO 10993-10, ISO 10993-23)
  • Software validation (IEC 62304) and cybersecurity
  • EMC and electrical safety (IEC 60601-1-2, IEC 60601-1, IEC 60601-2-18)
  • Human factors validation (IEC 62366-1)
  • Non-clinical performance testing against design specifications

Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.

How the review time compares

Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.

K253437 took 254 calendar days from receipt to decision. Of the latest 24 other decisions in product code BTR, 11 took longer, 13 were faster; their median was 248 days.

Latest decisions in BTR

NumberDevice and applicantDecision and review time
K251794 Tenax® Laser Resistant Endotracheal TubeBryan Medical, Inc. · Traditional Sep 3, 2026448 days
K253437 Spiro-VISTASpiro Robotics · Traditional Jun 12, 2026254 days
K250173 Shiley™ Oral RAE Tracheal Tube Cuffless, Murphy Eye (113-XX) Shiley™ Nasal RAE Tracheal Tube Cuffless, Murphy Eye (114-XX) Shiley™ Oral RAE Tracheal Tube Cuffed, Murphy Eye (115-XX) Shiley™ Oral RAE Tracheal Tube with TaperGuard™ Cuff, Murphy Eye (115-XXOR) Shiley™ Nasal RAE Tracheal Tube with TaperGuard™ Cuff, Murphy Eye (119-XXNR)Covidien, LLC · Traditional Oct 6, 2025258 days
K243785 Shiley™ Oral/Nasal Tracheal Tube with TaperGuard™ Cuff Reinforced, Murphy Eye Shiley™ Tracheal Tube TaperGuard™ Cuff Reinforced with Stylet Shiley™ Lo-Contour Oral/Nasal Tracheal Tube Cuffed Reinforced Shiley™ Lo-Contour Oral/Nasal Tracheal Tube Cuffed Reinforced, Murphy Eye Shiley™ Oral/Nasal Tracheal Tube Cuffless ReinforcedCovidien, LLC · Traditional Sep 25, 2025290 days
K243579 AeroJet Ventilation CatheterPipeline Medical Products, LLC · Traditional Aug 13, 2025267 days
K251499 Frova Intubating Introducer (C-CAE-14.0-70-FII, C-CAE-14.0-70-FI, C-CAE-14.0-70-FIC, C-CAE-14.0-70-FIC-SPOPS)William Cook Europe Aps · Special Jun 11, 202527 days
K250243 ProVu Single Use Video Stylet with Reinforced ET Tube (Size 6.5) (038-995-065U); ProVu Single Use Video Stylet with Reinforced ET Tube (Size 7.0) (038-995-070U); ProVu Single Use Video Stylet with Reinforced ET Tube (Size 7.5) (038-995-075U); ProVu Single Use Video Stylet with Reinforced ET Tube (Size 8.0) (038-995-080U)Flexicare Medical Limited. · Traditional May 20, 2025113 days
K242495 LMA Fastrach ETT SUTeleflex Medical · Traditional Apr 29, 2025250 days
K241451 Rusch Endotracheal Tubes (Reinforced, Safety Clear, Safety Clear Pediatric)Teleflex Incorporated · Traditional Feb 11, 2025265 days
K233341 Shiley™ Oral/Nasal Endotracheal Tube Intermediate Cuff, Non-DEHP (87430, 87435, 87440, 87445, 87450, 87455, 87460, 87465, 87470, 87475, 87480, 87485, 87490, 87495, 87410)Covidien, LLC · Traditional May 20, 2024234 days

Other 510(k)s from Spiro Robotics

The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.

This is the only 510(k) in openFDA under this applicant name.

Watch BTR in DeviceVigil

DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.

Add to Chrome — free Add to Edge

Get BTR every Monday

One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in BTR. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.