FDA device news · Product code PZO

FDA 510(k) clearance

Sim&Size (K253122): Sim&Cure 510(k) clearance

Montpellier, FR

Follow PZO: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Decision
Substantially Equivalent
Decision date
Dec 23, 2025
Received
Sep 25, 2025
510(k) type
Traditional
Product code
PZOSoftware For Visualization Of Vascular Anatomy And Intravascular Devices
Review panel
Radiology
Device class
Class II
Regulation
21 CFR 892.2050
Third-party review
No
Summary or statement
Summary
Review time
89 daysreceipt to decision, calendar days
Median in PZO
167 daysthe latest 9 other decisions
PZO decisions
1in the last 12 months
Applicant’s 510(k)s
6in openFDA, this one included

In plain English Written by AI

What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.

What it is
Sim&Size is a software as a medical device (software that runs on a computer and is regulated as a medical device) for simulating neurovascular implantable devices, meaning devices placed in the brain's blood vessels. It uses a 3D image of the patient's blood vessels made by 3D rotational angiography (a rotating X-ray scan that builds a 3D picture of blood vessels).
What it’s cleared for
Sim&Size is cleared to help clinicians visualize cerebral (brain) blood vessels for planning and sizing neurovascular interventions and surgery. It can also computationally model where neurointerventional devices would be placed. Its listed functions include segmentation of neurovascular structures, automatic centerline detection, 2D and 3D viewing of X-ray based images, placing and sizing tools, and reporting tools. The software does not replace the healthcare provider's judgment.
Compared with (the predicate)
How it differs
The summary describes the device as the same as its predicate in intended use, patient contact, image handling, computer compatibility, and image display. The new version adds more assessment outputs, such as relative sizing, pore density, and Spruce Index, and it expands the list of similar implantable devices in its database.
Testing the summary lists
  • Software verification and validation testing, documented per FDA guidance on device software functions
  • Non-clinical bench performance testing, documented per FDA guidance on bench performance testing
  • Verification testing comparing predicted device behavior with theoretical behavior
  • Retrospective in vivo testing comparing in vitro retrospective cases with virtual device simulation

Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.

How the review time compares

Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.

K253122 took 89 calendar days from receipt to decision. Of the latest 9 other decisions in product code PZO, 9 took longer; their median was 167 days.

Latest decisions in PZO

NumberDevice and applicantDecision and review time
K253122 Sim&SizeSim&Cure · Traditional Dec 23, 202589 days
K250160 ANKYRASMentice Spain S.L. · Traditional May 6, 2025105 days
K242124 Sim&SizeSim&Cure · Traditional Dec 14, 2024148 days
K230006 AnkyrasMentice Spain S.L. · Traditional Dec 28, 2023359 days
K222664 Sim&SizeSim&Cure · Traditional Jan 27, 2023147 days
K213838 AneuGuideArteryFlow Technology Co., Ltd. · Traditional Jun 1, 2022174 days
K212373 Sim&SizeSim&Cure · Traditional Jan 27, 2022181 days
K202322 Sim&SizeSim&Cure · Traditional Dec 31, 2020136 days
K190049 Sim&SizeSim&Cure · Traditional Sep 17, 2019250 days
K171534 SurgicalPreviewEndo Vantage, LLC · Traditional Nov 8, 2017167 days

Other 510(k)s from Sim&Cure

The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.

NumberDevice and applicantDecision and review time
K242124 Sim&SizeSim&Cure · Traditional Dec 14, 2024148 days
K222664 Sim&SizeSim&Cure · Traditional Jan 27, 2023147 days
K212373 Sim&SizeSim&Cure · Traditional Jan 27, 2022181 days
K202322 Sim&SizeSim&Cure · Traditional Dec 31, 2020136 days
K190049 Sim&SizeSim&Cure · Traditional Sep 17, 2019250 days

Watch PZO in DeviceVigil

DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.

Add to Chrome — free Add to Edge

Get PZO every Monday

One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in PZO. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.