FDA device news · Product code FMI

FDA 510(k) clearance

Pen Needle (K252886): Hh Global Technology, Inc. 510(k) clearance

Buford, GA

Follow FMI: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Decision
Substantially Equivalent
Decision date
Jan 6, 2026
Received
Sep 10, 2025
510(k) type
Traditional
Product code
FMINeedle, Hypodermic, Single Lumen
Review panel
General Hospital
Device class
Class II
Regulation
21 CFR 880.5570
Third-party review
No
Summary or statement
Summary
Review time
118 daysreceipt to decision, calendar days
Median in FMI
120 daysthe latest 24 other decisions
FMI decisions
12in the last 12 months
Applicant’s 510(k)s
2in openFDA, this one included

In plain English Written by AI

What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.

What it is
A sterile, single-use pen needle that screws onto a pen injector to inject drug under the skin (subcutaneous injection). It is offered in ordinary and safety versions, with a needle shield and, for safety types, a needle cover and spring that help protect against accidental needle sticks after use. Each needle comes individually packaged and sterilized by irradiation.
What it’s cleared for
The Indications for Use state that the Pen Needles are sterile, single-use needles intended for use with pen injector devices to inject drug. The summary lists both prescription and over-the-counter use, and says the device is intended for healthcare personnel, adult patients, and adult lay persons.
Compared with (the predicate)
How it differs
The summary says the subject device differs from predicate K220129 in trade name, over-the-counter versus prescription use labeling, sterilization method (irradiation instead of ethylene oxide), needle gauges (33G and 34G added), needle lengths (3.5mm, 10mm and 12mm added), and materials.
Testing the summary lists
  • Biocompatibility (ISO 10993-1, ISO 10993 series: cytotoxicity, skin irritation, sensitization, systemic toxicity, hemolysis, pyrogenicity)
  • Performance (ISO 9626, ISO 7864, ISO 11608-2)
  • Sterility and packaging (ISO 11137-2 radiation dose validation, USP <85> endotoxin, ASTM F88, F1929, F1886)
  • Shelf life (ASTM F1980-21 accelerated aging, 5 years)
  • Sharps injury protection (simulated clinical use study on 600 safety-configuration samples per ISO 23908:2011 and FDA sharps guidance)
  • Compatibility with pen injectors (ISO 11608-1 compliance claimed)

Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.

How the review time compares

Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.

K252886 took 118 calendar days from receipt to decision. Of the latest 24 other decisions in product code FMI, 13 took longer, 11 were faster; their median was 120 days.

Latest decisions in FMI

NumberDevice and applicantDecision and review time
K261266 MOWANA™ Auto DuoPENTAMASTER MEDIQ SDN BHD · Traditional Sep 17, 2026154 days
K261719 Promisemed X-Safety Pen NeedlePromisemed Hangzhou Meditech Co., Ltd. · Special Aug 25, 202691 days
K262427 Pen Needle (Ordinary Type I, Safety Type IIA, Safety Type IIB, Safety Type IIIA, Safety Type IIIB, Safety Type IV, Safety Type V, Ordinary Type VIA, Ordinary Type VIB, Ordinary Type VIC, Safety Type VII, Ordinary Type IB, Safety type VIII, Safety Type IX, Safety Type X, Ordinary Type XI, Safety Type XII)Hh Global Technology, Inc. · Special Aug 10, 202625 days
K260933 Safety Sterile Hypodermic Needles (NR-S1816R, NR-S1916R, NR-S1925R, NR-S1938R, NR-S2016R, NR-S2025R, NR-S2038R, NR-S2051R, NR-S2116R, NR-S2125R, NR-S2138R, NR-S2151R, NR-S2216R, NR-S2225R, NR-S2238R, NR-S2251R, NR-S2316R, NR-S2325R, NR-S2338R, NR-S2351R, NR-S2516R, NR-S2525R, NR-S2538R, NR-S2551R, NR-S2516T, NR-S2525T, NR-S2538T, NR-S2551T)Hangzhou Qiantang Longyue Biotechnology Co., Ltd. · Traditional Aug 7, 2026140 days
K261829 Profoject™ Dual-Safety Pen NeedlesCMT Health PTE., Ltd. · Traditional Jul 29, 202657 days
K260739 Profoject™ Pen Needles (Model A; Model B)CMT Health PTE., Ltd. · Traditional Jul 15, 2026131 days
K260855 Profoject™ Safety Pen NeedlesCMT Health PTE., Ltd. · Traditional Jun 10, 202686 days
K254273 Verisafe Safety Sterile Needles (SSN)Promisemed Hangzhou Meditech Co., Ltd. · Special Apr 16, 2026107 days
K252908 Easydrip Classic Pen Needle; Easydrip Plus Pen Needle; Easydrip Classic Pro Pen Needle; Easydrip Plus Pro Pen NeedleSandstone Medical (Suzhou), Inc. · Special Mar 25, 2026194 days
K253047 PRESSONE™Nipro Medical Corporation · Traditional Mar 24, 2026183 days

Other 510(k)s from Hh Global Technology, Inc.

The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.

NumberDevice and applicantDecision and review time
K262427 Pen Needle (Ordinary Type I, Safety Type IIA, Safety Type IIB, Safety Type IIIA, Safety Type IIIB, Safety Type IV, Safety Type V, Ordinary Type VIA, Ordinary Type VIB, Ordinary Type VIC, Safety Type VII, Ordinary Type IB, Safety type VIII, Safety Type IX, Safety Type X, Ordinary Type XI, Safety Type XII)Hh Global Technology, Inc. · Special Aug 10, 202625 days

Watch FMI in DeviceVigil

DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.

Add to Chrome — free Add to Edge

Get FMI every Monday

One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in FMI. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.