FDA device news · Product code GCJ
FDA 510(k) clearance
4K UHD Endoscopy Camera System (KMS-4K-2088, KMS-4K-2188, KMS-4K-2288) (K252858): Kms Medical Technology Co., Ltd. 510(k) clearance
Changsha, CN
- Decision
- Substantially Equivalent
- Decision date
- Apr 30, 2026
- Received
- Sep 9, 2025
- 510(k) type
- Traditional
- Product code
- GCJLaparoscope, General & Plastic Surgery
- Review panel
- Gastroenterology, Urology
- Device class
- Class II
- Regulation
- 21 CFR 876.1500
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 233 daysreceipt to decision, calendar days
- Median in GCJ
- 119 daysthe latest 24 other decisions
- GCJ decisions
- 27in the last 12 months
- Applicant’s 510(k)s
- 1in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- A 4K UHD (ultra high definition) endoscopy camera system made of a camera control unit and a camera head. The camera head converts light captured by a commercially available optical endoscope into electronic signals, and the control unit processes and records the images and sends them to a monitor.
- What it’s cleared for
- The system is cleared to convert optical signals from an optical endoscope, used with a cold light source and monitor, into electronic signals for imaging on a monitor. It can be used for both diagnostic and therapeutic interventions. The summary states the device is for use in professional healthcare facilities by specialized medical personnel, with adult patients listed as the target population.
- Compared with (the predicate)
- K180583, LOGIC 4K CAMERA CONTROLLER, LOGIC 4K CAMERA HEAD
- How it differs
- The summary says the proposed device has one 1/3 inch CMOS image sensor where the predicate has three, a different focal length range (14-32mm versus 13-29mm), and different minimum illumination and signal-to-noise figures.
- Testing the summary lists
- Biocompatibility not tested: the summary says ISO 10993-1 is not required because the device does not contact the patient
- Cleaning validation (AAMI ST98:2022), with no visible soil seen after cleaning
- Sterilization validation (ISO 17664-1:2021, SAL of 10^-6, low-temperature hydrogen peroxide plasma)
- Clinical testing: none
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K252858 took 233 calendar days from receipt to decision. Of the latest 24 other decisions in product code GCJ, 3 took longer, 21 were faster; their median was 119 days.
Latest decisions in GCJ
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K263459 | SWICS™Bloom Surgical, Inc. · Traditional | Oct 29, 202631 days |
| K262455 | da Vinci 5 Handheld Camera Head (470080); da Vinci 5 Handheld Camera Laparoscope, 0 degree (470081); da Vinci 5 Handheld Camera Laparoscope, 30 degree (470082); da Vinci 5 Handheld Camera Tray (400526); da Vinci 5 Firefly Imaging SystemIntuitive Surgical, Inc. · Traditional | Oct 14, 202689 days |
| K262397 | CuratOR EX2742Eizo Corporation · Traditional | Sep 11, 202659 days |
| K260884 | UNIDRIVE Select SystemKarl Storz SE & CO. KG · Traditional | Sep 1, 2026168 days |
| K260972 | OEV-271MUH LCD Monitor; OEV-321MUH LCD Monitor; OEV-431MUH LCD MonitorSony Corporation · Traditional | Aug 26, 2026155 days |
| K261139 | VereSee (VER150, VER200, VER151, VER201, VER200C, and VER-100-103)Freyja Healthcare, LLC · Traditional | Aug 13, 2026128 days |
| K253541 | EZ-Close™ (EZ Close Port Site Closing Device, EZ Close MAX Port Site Closing Device, EZ Close II Port Site Closing Device)Medical Impact · Traditional | Jul 24, 2026252 days |
| K261614 | LED LCD Monitor (OEV-271H)Lg Electronics.Inc · Traditional | Jul 17, 202663 days |
| K261249 | Universal Seal (5-12 mm)Intuitive Surgical, Inc. · Traditional | Jul 14, 202689 days |
| K260710 | FloShield Air System (FSS-01-1000T - 10mm, 0 Degree FloShield Air, FSS-02-1030T - 10mm, 30 Degree FloShield Air, FSS-03-1045T - 10mm, 45 Degree FloShield Air, FSS-01-0500T - 5mm, 0 Degree FloShield Air, FSS-02-0530T - 5mm, 30 Degree FloShield Air, FSS-01-0545T - 5mm, 45 Degree FloShield Air)FloShield, Inc. · Traditional | Jun 11, 202699 days |
Other 510(k)s from Kms Medical Technology Co., Ltd.
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
This is the only 510(k) in openFDA under this applicant name.
Watch GCJ in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get GCJ every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in GCJ. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K252858Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:GCJRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:GCJRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:GCJ AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Kms Medical Technology Co., Ltd."Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil