FDA device news · Product code GEI
FDA 510(k) clearance
F Care RF System (00MEDRF4000US, 05RAFAELOPROBE, 05SPHERAPROBE, 06OUTPUTKAB, 06Pedal1St) (K252704): F Care Systems USA, LLC 510(k) clearance
Miami, FL
- Decision
- Substantially Equivalent
- Decision date
- Nov 24, 2025
- Received
- Aug 27, 2025
- 510(k) type
- Traditional
- Product code
- GEIElectrosurgical, Cutting & Coagulation & Accessories
- Review panel
- General, Plastic Surgery
- Device class
- Class II
- Regulation
- 21 CFR 878.4400
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 89 daysreceipt to decision, calendar days
- Median in GEI
- 196 daysthe latest 25 other decisions
- GEI decisions
- 45in the last 12 months
- Applicant’s 510(k)s
- 4in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- The F Care RF System is a radiofrequency ablation system. It uses the MedRF4000 electrosurgical generator, two single-use monopolar electrodes (the Rafaelo and Sphera probes), an output cable and a foot pedal. The generator sends radiofrequency energy through the probe tip, where it turns into heat in the tissue and causes coagulation, which means the tissue is sealed or clotted.
- What it’s cleared for
- The system is cleared to conduct radiofrequency current from the generator to target soft tissue for coagulation in a broad range of surgical procedures. It is a prescription device intended for trained healthcare professionals.
- How it differs
- The summary says the Sphera probe has a rounded tip, while the predicate's tip is sharp, and it is shorter at 3 mm instead of 10 mm. The electrodes also use a different stainless steel subtype (304L instead of 316L), a chromium nitride anti-stick coating on the tip, and PFA insulation instead of PTFE.
- Testing the summary lists
- Biocompatibility (ISO 10993-1)
- Thermal effects, ex-vivo porcine tissue study compared with the predicate
- Electrical safety (IEC 60601-1, IEC 60601-2-2)
- Electromagnetic compatibility (IEC 60601-1-2)
- Software verification and validation (IEC 62304)
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K252704 took 89 calendar days from receipt to decision. Of the latest 25 other decisions in product code GEI, 21 took longer, 4 were faster; their median was 196 days.
Latest decisions in GEI
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K262720 | SP Electrocautery Device (SP18 Max, SP20 Max)Single Pass, Inc. · Traditional | Oct 26, 202687 days |
| K262386 | SafeAir Electrosurgical Generator with Smoke Evacuation (0795-001-000); SafeAir Generator 3-Pedal Footswitch (0795-007-000)Stryker Instruments · Traditional | Oct 20, 202699 days |
| K254196 | HARMONIC 1100 Shears (HAR1120, HAR1136)Ethicon Endo-Surgery, LLC · Traditional | Sep 17, 2026268 days |
| K261959 | Neptune® SafeAir® 10ft Smoke Evacuation Pencil, Square Coated, 70mm Blade, Push Button Switch (0703-046-100); Neptune® SafeAir® 10ft Smoke Evacuation Pencil, Square Coated, Push Button Switch, Bulk Non-Sterile (0703-046-102); Neptune® SafeAir® 10ft Smoke Evacuation Pencil, Square Coated, 70mm Blade, Rocker Switch (0703-047-100); Neptune® SafeAir® 10ft Smoke Evacuation Pencil, Square Coated, Rocker Switch, Bulk Non-Sterile (0703-047-102)Stryker Instruments · Special | Sep 17, 202698 days |
| K261070 | LigaSure™ RAS Maryland Jaw Vessel Sealer/Divider, Nano-coatedCovidien, LLC · Traditional | Sep 15, 2026167 days |
| K254185 | Potenza PrimeJeisys Medical Incorporated · Traditional | Sep 11, 2026262 days |
| K262364 | Ellian Enigma RF DeviceEllian Corp · Traditional | Sep 2, 202654 days |
| K253859 | Scarlet Pro (Scarlet Pro)VIOL Co., Ltd. · Traditional | Aug 27, 2026267 days |
| K252535 | Inno-Switch™ Laparoscopic InstrumentsTaiwan Surgical Corporation · Traditional | Aug 25, 2026378 days |
| K261179 | AlphaTriPart - Monopolar MIC InstrumentsGimmi GmbH · Traditional | Jul 22, 2026103 days |
Other 510(k)s from F Care Systems USA, LLC
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K253918 | Veineo System (00MEDRF4000TCUS 05CR45iT 06Pedal1St)F Care Systems USA, LLC · Traditional | Jun 2, 2026176 days |
| K220725 | HPR45iF Care Systems USA, LLC · Traditional | Mar 20, 2023371 days |
| K210077 | MED RF 4000F Care Systems USA, LLC · Traditional | Dec 17, 2021339 days |
Watch GEI in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get GEI every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in GEI. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K252704Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:GEIRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:GEIRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:GEI AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"F Care Systems USA, LLC"Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil