FDA device news · Product code QVS
FDA 510(k) clearance
Explant Express (K252438): Applied Medical Technology, Inc. 510(k) clearance
Brecksville, OH
- Decision
- Substantially Equivalent
- Decision date
- Feb 3, 2026
- Received
- Aug 1, 2025
- 510(k) type
- Traditional
- Product code
- QVSBreast Implant Suction Retrieval Device
- Review panel
- General, Plastic Surgery
- Device class
- Class II
- Regulation
- 21 CFR 878.4675
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 186 daysreceipt to decision, calendar days
- Median in QVS
- 150 daysthe latest 1 other decisions
- QVS decisions
- 1in the last 12 months
- Applicant’s 510(k)s
- 25in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- The Explant Express is a single-use suction device made of a rigid plastic container with a nozzle at one end and a vacuum port at the other. It attaches to operating room suction and is used to draw material out of a breast implant. The container has two separable halves and an O-ring that seals them together.
- What it’s cleared for
- It is cleared to assist in the removal of one intracapsular ruptured silicone breast implant. It is not intended for en bloc removal, for removing residual silicone, or for direct application to tissue. The summary's Indications for Use section also states contraindications for patients with prior breast reconstruction or with tissue characteristics incompatible with device use, such as previous mastectomy, radiation, compromised vascularity, or ulceration.
- Compared with (the predicate)
- DEN220082, BIRD (previously known as the Bateman Bottle)
- Testing the summary lists
- Software, interconnectivity, EMC and electrical safety: not applicable, since the device is purely mechanical
- Human factors and usability validation (FDA human factors guidance, 2016)
- Animal study in a GLP porcine model with ruptured implants, evaluated macroscopically and histologically; no clinical study was conducted
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K252438 took 186 calendar days from receipt to decision. Of the latest 1 other decision in product code QVS, 1 was faster; their median was 150 days.
Latest decisions in QVS
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K252438 | Explant ExpressApplied Medical Technology, Inc. · Traditional | Feb 3, 2026186 days |
| DEN220082 | Breast Implant Removal Device (BIRD)Gaylord Solutions, LLC · Direct | Apr 20, 2023150 days |
Other 510(k)s from Applied Medical Technology, Inc.
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K240514 | AMT Low-Profile Suprapubic Catheter & Drainage SetApplied Medical Technology, Inc. · Traditional | Nov 1, 2024253 days |
| K241111 | AMT Suture PasserApplied Medical Technology, Inc. · Traditional | Jul 5, 202474 days |
| K222846 | AMT G-Tube Balloon Gastrostomy Feeding DeviceApplied Medical Technology, Inc. · Traditional | Dec 18, 2023453 days |
| K202539 | Nutriglide(TM) Nasal Feeding TubeApplied Medical Technology, Inc. · Traditional | Oct 29, 202057 days |
| K193612 | AMT Suture Delivery SystemApplied Medical Technology, Inc. · Traditional | Mar 12, 202077 days |
| K183508 | Micro Transgastric-Jejunal Feeding DeviceApplied Medical Technology, Inc. · Traditional | Mar 29, 2019101 days |
| K182804 | Traditional Length GJ Feeding DeviceApplied Medical Technology, Inc. · Traditional | Mar 1, 2019150 days |
| K180026 | Bowel Management Device, Bowel Management Irrigation SetApplied Medical Technology, Inc. · Traditional | Jun 1, 2018149 days |
| K170319 | Low Profile Non-Balloon Feeding DeviceApplied Medical Technology, Inc. · Traditional | Oct 6, 2017247 days |
| K161413 | Low Profile Balloon Feeding DeviceApplied Medical Technology, Inc. · Traditional | Feb 9, 2017262 days |
| K150034 | AMT Enteral Transition AdaptersApplied Medical Technology, Inc. · Traditional | Jun 9, 2015151 days |
| K142971 | AMT Bridle - Nasal Tube Retention SystemApplied Medical Technology, Inc. · Traditional | May 26, 2015224 days |
Watch QVS in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get QVS every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in QVS. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K252438Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:QVSRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:QVSRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:QVS AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Applied Medical Technology, Inc."Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil