FDA device news · Product code BZG
FDA 510(k) clearance
MESI mTABLET SPIRO (K251777): Mesi D.O.O. 510(k) clearance
Ljubljana, SI
- Decision
- Substantially Equivalent
- Decision date
- Mar 2, 2026
- Received
- Jun 10, 2025
- 510(k) type
- Traditional
- Product code
- BZGSpirometer, Diagnostic
- Review panel
- Anesthesiology
- Device class
- Class II
- Regulation
- 21 CFR 868.1840
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 265 daysreceipt to decision, calendar days
- Median in BZG
- 215 daysthe latest 24 other decisions
- BZG decisions
- 2in the last 12 months
- Applicant’s 510(k)s
- 5in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- The MESI mTABLET SPIRO is an automated wireless spirometer, a device that measures how much air a person can breathe out and how fast, to help assess lung function. It pairs a wireless tablet with a spirometer module and disposable mouthpieces.
- What it’s cleared for
- The device is cleared to assess respiratory function by measuring dynamic lung volumes (spirometry) in adults and children ages 5 years and older. It reports FVC, FEV1, FEV6, and VC. It is meant to be operated by medical professionals in primary care facilities, hospitals, and health centers.
- How it differs
- The summary says the device uses a wireless tablet-based design with Bluetooth and Wi-Fi, while the predicate is a standalone spirometer. It samples flow at 800 Hz instead of 100 Hz, has a larger maximum displaced volume (14 L instead of 10 L), and reports fewer parameters (no PEF or MVV).
- Testing the summary lists
- Spirometry performance (ATS/ERS 2019; ISO 26782:2009)
- Biocompatibility (ISO 10993-5, -10, -18; ISO 18562-2, -3)
- Electrical safety (AAMI ANSI ES 60601-1:2005 + A1:2012) and EMC (IEC 60601-1-2:2014)
- Wireless coexistence (ANSI/IEEE C63.27:2017)
- Software verification and validation, with cybersecurity documentation
- Reprocessing validation of the reusable aluminum housing (AAMI ST98)
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K251777 took 265 calendar days from receipt to decision. Of the latest 24 other decisions in product code BZG, 8 took longer, 16 were faster; their median was 215 days.
Latest decisions in BZG
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K260990 | Model 7000 SpirotracVitalograph , Ltd. · Traditional | Nov 4, 2026224 days |
| K251777 | MESI mTABLET SPIROMesi D.O.O. · Traditional | Mar 2, 2026265 days |
| K241843 | TD-7301 Spirometer (TD-7301)Gostar Co., Ltd. · Traditional | Nov 20, 2024147 days |
| K231416 | Air Next (NVD-02)Nuvoair AB · Traditional | Jan 18, 2024247 days |
| K230501 | Spirobank OxiMir Medical International Research USA · Traditional | Dec 15, 2023294 days |
| K230178 | EasyOne Sky SpirometerNdd Medizintechnik AG · Traditional | Oct 19, 2023269 days |
| K222525 | Alveoair Digital SpirometerRoundworks Technologies Private Limited · Traditional | Aug 28, 2023371 days |
| K222443 | Air Smart Extra SpirometerFeellife Health, Inc. · Traditional | Aug 9, 2023362 days |
| K213754 | SpiroHome Personal, SpiroHome ClinicInofab Saglik Teknolojileri A.S · Traditional | Jun 12, 2023559 days |
| K213872 | ComPAS2Morgan Scientific, Inc. · Traditional | Jul 15, 2022214 days |
Other 510(k)s from Mesi D.O.O.
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K223670 | MESI mTablet ECG Diagnostic System, MESI mTablet ECGMesi, Development of Medical Devices, Ltd.; Mesi D.O.O. · Traditional | Jul 28, 2023233 days |
| K213730 | MESI mTABLET TBI diagnostic system, MESI mTABLET TBIMesi, Development of Medical Devices, Ltd.; Mesi D.O.O. · Traditional | Apr 21, 2022146 days |
| K201046 | Automated ankle brachial pressure index measuring device, MESI mTABLET systemMesi D.O.O.; Mesi, Development of Medical Devices, Ltd. · Traditional | Dec 11, 2020234 days |
| K172655 | Automated ankle brachial pressure index measuring deviceMesi D.O.O.; Mesi, Development of Medical Devices, Ltd. · Traditional | Jan 11, 2018128 days |
Watch BZG in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get BZG every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in BZG. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K251777Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:BZGRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:BZGRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:BZG AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Mesi D.O.O."Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil