FDA device news · Product code QJF

FDA 510(k) clearance

Swift Ray 1 (K251678): Swift Medical, Inc. 510(k) clearance

Toronto, CA

Follow QJF: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Decision
Substantially Equivalent
Decision date
Feb 24, 2026
Received
May 30, 2025
510(k) type
Traditional
Product code
QJFAutofluorescence Imaging Adjunct Tool For Wounds
Review panel
General, Plastic Surgery
Device class
Class II
Regulation
21 CFR 878.4550
Third-party review
No
Summary or statement
Summary
Review time
270 daysreceipt to decision, calendar days
Median in QJF
178 daysthe latest 6 other decisions
QJF decisions
1in the last 12 months
Applicant’s 510(k)s
1in openFDA, this one included

In plain English Written by AI

What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.

What it is
The Swift Ray 1 is a portable digital imaging system that works with a smartphone over Bluetooth Low Energy. It captures ordinary photographs of a wound, measures wound size, records fluorescence (light emitted by bacteria when exposed to a special excitation light), and records thermographic images (heat maps made with long-wave infrared sensing) to show temperature differences across the wound.
What it’s cleared for
The Swift Ray 1 is cleared for clinicians diagnosing and treating wounds at the point of care. It can view and digitally record wound images, measure and record wound size, and record fluorescence and thermographic images. The fluorescence image, used together with clinical signs and symptoms, has been shown to increase the likelihood that clinicians identify wounds with bacterial loads above 10^4 CFU per gram compared with clinical signs and symptoms alone.
Compared with (the predicate)
How it differs
The summary says the Swift Ray 1 has additional multispectral imaging capabilities that enable thermal imaging, and that its thermal and bacterial modules operate independently with separate controls and outputs.
Testing the summary lists
  • Software verification and validation, including wireless stability, data integrity, image acquisition, power management, and error handling
  • Cybersecurity risk management for wireless communication, access control, and data transmission
  • Clinical accuracy study of 53 chronic wounds at two sites
  • Repeatability and reproducibility study of 25 wounds and 600 images at one site

Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.

How the review time compares

Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.

K251678 took 270 calendar days from receipt to decision. Of the latest 6 other decisions in product code QJF, 6 were faster; their median was 178 days.

Latest decisions in QJF

NumberDevice and applicantDecision and review time
K251678 Swift Ray 1Swift Medical, Inc. · Traditional Feb 24, 2026270 days
K242669 SnapshotGLO (KB100)Kent Imaging, Inc. · Traditional Mar 26, 2025202 days
K230734 Multispectral Imager Kit (MSI Kit) (300-00015), Multispectral Imager (MSI) (300-00009)Precision Healing, LLC · Traditional Dec 5, 2023264 days
K213840 MolecuLight I:XMolecuLight, Inc. · Traditional May 18, 2022160 days
K211901 MolecuLightDXMolecuLight, Inc. · Special Jul 21, 202130 days
K210882 MolecuLight I:XMolecuLight, Inc. · Traditional Jun 22, 202189 days
K191371 MolecuLight i:XMolecuLight, Inc. · Traditional Dec 4, 2019196 days

Other 510(k)s from Swift Medical, Inc.

The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.

This is the only 510(k) in openFDA under this applicant name.

Watch QJF in DeviceVigil

DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.

Add to Chrome — free Add to Edge

Get QJF every Monday

One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in QJF. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.