FDA device news · Product code QVB

FDA 510(k) clearance

InstaTRU Instant Biological Indicator for Steam (IBI-05) (K251559): True Indicating, LLC 510(k) clearance

Toledo, OH

Follow QVB: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Decision
Substantially Equivalent
Decision date
Jun 18, 2026
Received
May 21, 2025
510(k) type
Traditional
Product code
QVBBiological Sterilization Indicator With Indirect Growth Detection
Review panel
General Hospital
Device class
Class II
Regulation
21 CFR 880.2806
Third-party review
No
Summary or statement
Summary
Review time
393 daysreceipt to decision, calendar days
Median in QVB
507 daysthe latest 2 other decisions
QVB decisions
2in the last 12 months
Applicant’s 510(k)s
6in openFDA, this one included

In plain English Written by AI

What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.

What it is
The InstaTRU Instant Biological Indicator for Steam (IBI-05) is a test device that checks whether a steam sterilizer has killed microorganisms. It has a polypropylene vial holding a tablet containing at least 10^5 Geobacillus stearothermophilus spores. After the tablet is exposed to steam, adding the supplied Indicator Solution triggers an enzyme reaction that gives a visible color result within 20 seconds.
What it’s cleared for
It is cleared for routine monitoring of steam sterilization processes and for monitoring processed loads, giving a visual result in 20 seconds. The summary says it is not recommended for qualification testing.
Compared with (the predicate)
  • DEN220042, Terragene Bionova Photon Biological Indicator (BT225)
How it differs
The summary says the device uses an enzyme reaction with a qualitative result, while the predicate uses fluorescence detection with a quantitative result. The device does not need a reader and has no chemical indicator, and its hold time is 72 hours compared with 14 days for the predicate.
Testing the summary lists
  • Spore population, D value and z value (ISO 11138-1, ISO 11138-3)
  • Survival time and kill time (ISO 11138-1, ISO 11138-3, FDA guidance)
  • Reduced incubation time (10 hours) and hold time (72 hours)
  • End point color stability (7 days)
  • Probable limit of detection, sensitivity and specificity
  • Simulated use in a sterilizer

Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.

How the review time compares

Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.

K251559 took 393 calendar days from receipt to decision. Of the latest 2 other decisions in product code QVB, 1 took longer, 1 was faster; their median was 507 days.

Latest decisions in QVB

NumberDevice and applicantDecision and review time
K251559 InstaTRU Instant Biological Indicator for Steam (IBI-05)True Indicating, LLC · Traditional Jun 18, 2026393 days
K252306 Verrix EVA™ STEAM Biological Indicator (BI) (Model: 1200), Verrix EVA™ STEAM Process Challenge Device (PCD) (Model: 1300) combined with Verrix EVA™ Auto-Reader (Model: 1100)Steritec Products · Traditional Apr 22, 2026272 days
DEN220042 Terragene Bionova Photon Biological Indicator (BT225); Terragene Bionova Photon Auto-Reader Incubator (BPH)Terragene S.A. · Direct Jul 12, 2024742 days

Other 510(k)s from True Indicating, LLC

The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.

NumberDevice and applicantDecision and review time
K242860 Type 5 Integrating Indicator for Steam (CSPN-15)True Indicating, LLC · Traditional Jan 17, 2025119 days
K233413 Ultraphon Chemical Indicator (TRO-T and TRO-B)True Indicating, LLC · Traditional Jun 26, 2024264 days
K220778 Chemical Indicator for SteamTrue Indicating, LLC · Traditional Dec 2, 2022260 days
K210481 Instant 20s IndicatorTrue Indicating, LLC · Traditional Dec 14, 2021298 days
K200970 Self-Contained Biological IndicatorTrue Indicating, LLC · Traditional Dec 28, 2020259 days

Watch QVB in DeviceVigil

DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.

Add to Chrome — free Add to Edge

Get QVB every Monday

One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in QVB. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.