FDA device news · Product code QVB
FDA 510(k) clearance
InstaTRU Instant Biological Indicator for Steam (IBI-05) (K251559): True Indicating, LLC 510(k) clearance
Toledo, OH
- Decision
- Substantially Equivalent
- Decision date
- Jun 18, 2026
- Received
- May 21, 2025
- 510(k) type
- Traditional
- Product code
- QVBBiological Sterilization Indicator With Indirect Growth Detection
- Review panel
- General Hospital
- Device class
- Class II
- Regulation
- 21 CFR 880.2806
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 393 daysreceipt to decision, calendar days
- Median in QVB
- 507 daysthe latest 2 other decisions
- QVB decisions
- 2in the last 12 months
- Applicant’s 510(k)s
- 6in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- The InstaTRU Instant Biological Indicator for Steam (IBI-05) is a test device that checks whether a steam sterilizer has killed microorganisms. It has a polypropylene vial holding a tablet containing at least 10^5 Geobacillus stearothermophilus spores. After the tablet is exposed to steam, adding the supplied Indicator Solution triggers an enzyme reaction that gives a visible color result within 20 seconds.
- What it’s cleared for
- It is cleared for routine monitoring of steam sterilization processes and for monitoring processed loads, giving a visual result in 20 seconds. The summary says it is not recommended for qualification testing.
- Compared with (the predicate)
- DEN220042, Terragene Bionova Photon Biological Indicator (BT225)
- How it differs
- The summary says the device uses an enzyme reaction with a qualitative result, while the predicate uses fluorescence detection with a quantitative result. The device does not need a reader and has no chemical indicator, and its hold time is 72 hours compared with 14 days for the predicate.
- Testing the summary lists
- Spore population, D value and z value (ISO 11138-1, ISO 11138-3)
- Survival time and kill time (ISO 11138-1, ISO 11138-3, FDA guidance)
- Reduced incubation time (10 hours) and hold time (72 hours)
- End point color stability (7 days)
- Probable limit of detection, sensitivity and specificity
- Simulated use in a sterilizer
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K251559 took 393 calendar days from receipt to decision. Of the latest 2 other decisions in product code QVB, 1 took longer, 1 was faster; their median was 507 days.
Latest decisions in QVB
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K251559 | InstaTRU Instant Biological Indicator for Steam (IBI-05)True Indicating, LLC · Traditional | Jun 18, 2026393 days |
| K252306 | Verrix EVA™ STEAM Biological Indicator (BI) (Model: 1200), Verrix EVA™ STEAM Process Challenge Device (PCD) (Model: 1300) combined with Verrix EVA™ Auto-Reader (Model: 1100)Steritec Products · Traditional | Apr 22, 2026272 days |
| DEN220042 | Terragene Bionova Photon Biological Indicator (BT225); Terragene Bionova Photon Auto-Reader Incubator (BPH)Terragene S.A. · Direct | Jul 12, 2024742 days |
Other 510(k)s from True Indicating, LLC
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K242860 | Type 5 Integrating Indicator for Steam (CSPN-15)True Indicating, LLC · Traditional | Jan 17, 2025119 days |
| K233413 | Ultraphon Chemical Indicator (TRO-T and TRO-B)True Indicating, LLC · Traditional | Jun 26, 2024264 days |
| K220778 | Chemical Indicator for SteamTrue Indicating, LLC · Traditional | Dec 2, 2022260 days |
| K210481 | Instant 20s IndicatorTrue Indicating, LLC · Traditional | Dec 14, 2021298 days |
| K200970 | Self-Contained Biological IndicatorTrue Indicating, LLC · Traditional | Dec 28, 2020259 days |
Watch QVB in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get QVB every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in QVB. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K251559Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:QVBRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:QVBRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:QVB AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"True Indicating, LLC"Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil