FDA device news · Product code DZE

FDA 510(k) clearance

NizPlant Dental Implant System (K250476): Paragon Implant Mfg., LLC 510(k) clearance

Calabasas, CA

Follow DZE: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Decision
Substantially Equivalent
Decision date
Dec 23, 2025
Received
Feb 19, 2025
510(k) type
Abbreviated
Product code
DZEImplant, Endosseous, Root-Form
Review panel
Dental
Device class
Class II
Regulation
21 CFR 872.3640
Third-party review
No
Summary or statement
Summary
Review time
307 daysreceipt to decision, calendar days
Median in DZE
191 daysthe latest 24 other decisions
DZE decisions
19in the last 12 months
Applicant’s 510(k)s
5in openFDA, this one included

In plain English Written by AI

What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.

What it is
The NizPlant Dental Implant System is a set of root-form endosseous dental implants, which are small titanium screw-like posts placed into the jawbone, plus abutments and other restorative parts used to plan, place and support replacement teeth for edentulous (toothless) patients.
What it’s cleared for
The implants are cleared for single-stage surgical placement in edentulous or partially edentulous mandibles or maxillae (lower or upper jaws) to support complete denture prostheses, or fixed or removable bridgework for multi-unit tooth replacement. The summary says they may be used for immediate function when initial implant stability has been achieved and with appropriate occlusal loading. Short implants (under 9mm) are indicated for multiple-unit restorations where vertical bone volume is limited.
Compared with (the predicate)
  • K090234, Spectra-System Dental Implants 2008
How it differs
The summary says the device is indicated for multi-unit tooth replacement, while the predicate covers single-tooth and multi-tooth replacement, and the device adds short implants for limited vertical bone.
Testing the summary lists
  • Chemical characterization and biocompatibility (ISO 10993, ISO 7405)
  • Sterilization validation (ANSI/AAMI/ISO 11137-2)
  • Cleaning and sterilization validation for non-sterile devices (ISO 17664-1, AAMI TIR12, ISO 17665)
  • MRI safety simulation and physical testing (ASTM F2052, F2119, F2182, F2213)
  • Packaging accelerated aging, sterile barrier shelf-life, and transportation simulation (ASTM F1980-21, ISO 11737-2, ASTM D4169, F7386)
  • Surface characterization, SEM/EDS analysis, endotoxin testing, in silico short-implant modeling, and pullout load testing

Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.

How the review time compares

Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.

K250476 took 307 calendar days from receipt to decision. Of the latest 24 other decisions in product code DZE, 4 took longer, 20 were faster; their median was 191 days.

Latest decisions in DZE

NumberDevice and applicantDecision and review time
K261295 MultiNeO Dental Implant SystemAlpha Bio Tec , Ltd. · Traditional Oct 22, 2026185 days
K261392 TriActive Dental Implant SystemParagon Implant Mfg., LLC · Abbreviated Sep 17, 2026141 days
K260463 ZEROS Dental Implant SystemZeros Co., Ltd. · Special Aug 19, 2026188 days
K251188 UNIQA® Dental Implants SystemUniqa Dental, Ltd. · Traditional Jun 25, 2026434 days
K250806 Dental Implant SystemA.B. Dental Devices , Ltd. · Traditional Jun 18, 2026458 days
K251232 MegaGen Zygoma Dental Implant SystemMegagen Implant Co., Ltd. · Traditional Jun 18, 2026422 days
K260006 INOSS SystemInosys, Inc. · Traditional Jun 17, 2026166 days
K252731 Promimic ZrP Surface Dental Implant; Promimic ZrP + HAnano Surface Dental ImplantPromimic AB · Traditional May 12, 2026257 days
K252031 Adin Long Dental Implant SystemAdin Dental Implant Systems , Ltd. · Traditional Mar 23, 2026266 days
K253334 ZENEX Implant System_Short (R-System)Izenimplant Co., Ltd. · Traditional Mar 16, 2026167 days

Other 510(k)s from Paragon Implant Mfg., LLC

The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.

NumberDevice and applicantDecision and review time
K261392 TriActive Dental Implant SystemParagon Implant Mfg., LLC · Abbreviated Sep 17, 2026141 days
K252145 GEN5™ and GEN5+™ 3.3mmD Dental ImplantsParagon Implant Mfg., LLC · Traditional Dec 23, 2025167 days
K251756 Sterilization TraysParagon Implant Mfg., LLC · Traditional Nov 14, 2025158 days
K251938 GEN5 and GEN5+ Dental Implant SystemParagon Implant Mfg., LLC · Traditional Oct 30, 2025128 days

Watch DZE in DeviceVigil

DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.

Add to Chrome — free Add to Edge

Get DZE every Monday

One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in DZE. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.